Browse

FSI DAT® QE SERIES® Patent Pending

 

'Quick Erect' SHOWER SYSTEMS

 

GENERAL SPECIFICATIONS


Patent pending lattice framework retractable, corrosion resistant, coated, lightweight aluminum
• Heavy Duty
• Rapid Deployment
• Multiple Models/Sizes
• Structurally Superior and Incredibly Stable in High Winds up to 70 MPH (115 Kph)


Frame: Heavy duty patent pending lattice framework retractable, corrosion resistant, coated, lightweight aluminum tubing. Frame supports 250 lb./114 Kg hang weight +. Width: 45mm Thickness: 1.2 mm Weight: 570g / m2 Tensile strength: 17 Kg/ mm2 Elongation: 10 %


Canopy: Heavy duty 100% nylon twill (3/5) w. PU white pigment inner coating, ABT. 0 23mm X 57/58. Wt. AB1.230GR/Sq. M - UV/chemical resistant/fire retardant – UV resistant and water repellent w. a hydrostatic resistance of 250 psi + - Mildew resistant to meet and exceed US Fed. Test MIL.STD.810E 508 - Fire resistance meets and exceeds CPAI 84 SECTION 5 1995, US Fed. Test CFR.1610, meets NFPA701 Flammability Test method 1 (2004), NFPA 702 w. ‘A’ burn scale rating.


Floor: 1,000 denier Nylon coated w. PU, tensile strength: 2545N/2360, Tear Strength: 106/102N, weight: 490 g/yd.


Frame: DAT QE Frame Material Specifications, Dimensions:

•Outer Diameter: 15.72±0.25
•Wall Thickness: 1.68±0.25
•Carbon Content: 25±2.0%
•Specific Gravity: 1.8~2.1
*All testing below use ASTM and National Test standards


Mechanical Properties:

•Tensile Strength (ASTM D638, National GB1447-83): L=3000~5200 KG/Cm²; T=2000~5000 KG/Cm²
•Tensile Modulus (ASTM D638, National GB1447-83): L= 3.8~6.7×105 ; T= 1.5~6.0×105 KG/Cm²
•Flexural Strength (ASTM D790, National GB1449-83): L= 3000~6200; T=2500~5000 KG/Cm²
•Flexural Modulus (ASTM D790, National GB1449-83): L=4.9~12.6X105 ; T=1.8~10.6X105 KG/Cm²
•Compressive Strength (ASTM D695, National GB1448-83): L=2000~4000; T=1480~3480 KG/Cm²
•Shear Strength (ASTM D732, National GB1450-83): L=4540~8600; T=2540~6600 KG/Cm²
•Izod Impact Strength(V Type) (ASTM D256, National GB1451-83): L=250~900; T=200~700 KG.CM/ Cm²

 

Electrical Properties:

Volume Resistance (ASTM D257, National GB1410-78): 1012~1015 Ω.CM
Surface Resistance (ASTM D257, National GB1470-78): 1012~1015 Ω
Dielectric Constant (ASTM D150, National GB1409-79): 3~5
Dissipation Factor (ASTM D150, National GB1409-79): 0.05
Breakdown Voltage (ASTM D149, National GB1408-78): 13~40 KV/mm
Arc Resistance (ASTM D495, GB1411-78): 60~80(S)

QE SERIES® ‘Quick Erect’ General Set up and Tear down Instructions:


Standard color is ‘FSI’ Blue exterior w. high visibility white inside color. Green and White exterior canopy color also available at no extra cost. Other colors available P.O.A.


All Shelters have full privacy zipper closure and full screen zipper closure slip in and out dirty entry/clean exit doors, tie down ropes and 4 D-rings to tie off to, repair kit, manual, carry bag, 2 upper air vents, and a hammer.


All canopy walls are velcro’d to the frame and flooring for air lock, and reflective striping is found on the upper air vents above doors. Units can attach to a second shower or FSI shelter. Simply unfold/pop up the unit and commence use in approx. 1 - 4 minutes (size of shelter dependent).


Every FSI DAT® QE series® shelter comes complete w. no charge redundant features allowing for - hanging undress/redress kits etc. on the inlet and outlet side.


All DAT® QE series® shelters available with cross and center divider curtains, side doors, extra windows, skylights, HVAC/clothing ducts with ties, etc. as offered in published FSI price lists and at www.fsinorth.com


Multiple optional accessories available inclusive of air heaters, air coolers, elevation grids, waste water pumps, etc. available.

 

 


Currently not offered for sale in the USA.



Order by:     Display #  

DAT QE 2020S

DAT QE2020S Approx. 7’ W X 7’ L X 8’ H, 50 sq. Ft., 99 lbs. 6 spray nozzle heads, one Multi function Trigger gun. First Responder Portable Haz mat Decon shower system complete.  Product Details...


DAT QE2525S

DAT QE2525S approx. 7' W X 13' L X 8' H, with 4 ft. Undress/5 ft. Shower/4 ft. Redress areas. A First Responder Ambulatory Decon shower system with 6 spray nozzles and 1 trigger gun, 90 sq. ft., 145 lbs.  Product Details...


DAT QE2525SMA

DAT2525SMA approx. 7' W X 13' L X 8' H, w. 3 ft. Undress/7 ft. Shower/3 ft. Redress areas. A Single line Ambulatory and/or Non-Ambulatory Decon shower system with 6 spray nozzles and 2 multiple function trigger guns, 90 sq. ft., 145 lbs.  Product Details...


DAT QE2626S

Single wide stretcher decon shower system to handle 1 non-ambulatory victim w. attendants, 4 multiple function trigger guns, approx. 7'W X 13'L X 8'H, 90 sq. ft., 145 lbs.  Product Details...


DAT QE3030S

Approx. 10’ W X 10’ L X 9’ H, 100 sq. Ft., 115 lbs.2 Line Mass Casualty Decon Shower System that can handle two non-ambulatory stretchers or 4 ambulatory personnel or combinations or the above  Product Details...


DAT QE3060S

3 line 3 or 4 stage Mass Casualty Decon Shower System can decon 3 to 6 ambulatory, 3 non-ambulatory, or any combination. Undress/Detergent Shower/Rinse Shower/Redress configuration. Also comes w. center divider curtain at N/C to turn unit into a very lar  Product Details...


DAT QE3535S

2-Line 3 or 4 stage Mass Casualty Decon Shower System, Approx. 10' W X 15" L X 9' H, 150 sq. ft., 165 lbs., Undress/Detergent Shower/Rinse Shower/Redress configuration. Decon 2 to 4 ambulatory personnel, 2 non-ambulatory or any combination at one time. E  Product Details...





Display #  