DAT3030-IS-SUVDAT3370-IS

DAT3060-IS

PDFPrint
DAT3060_IS.jpg

FSI DAT Series Isolation Shelter - Approx. 11’ W X 21’ L X 9’ H (3.3 M X 6.4 M X 2.7 M) – Shelter only w. double door 'airlock', 231 sq. Ft. (21 M2) 250 lbs. (113 Kg), full velcro closure air vents, clear vinyl windows, HVAC Air ducts w. tie closures

Description

FSI DAT Series Isolation Shelter - Approx. 11’ W X 21’ L  X  9’ H (3.3 M X 6.4 M X 2.7 M) – Shelter only w. double door 'airlock',  231 sq. Ft. (21 M2)  250 lbs. (113 Kg), full velcro closure air vents, clear vinyl windows, HVAC Air ducts w. tie closures

Files:
Name File size    
decon_manual_2016 5.92 MB

Technical Specs

FSI # DAT® SERIES PNEUMATIC ISOLATION SHELTERS FROM FSI

ALL ISOLATION SHELTERS REGARDLESS OF SIZE

 

GENERAL SPECIFICATIONS

 

Air pressure internally once inflated = 4.3 psi (0.3 bar)

USA Federal Standard FS # 191 5041/5102/5134/5970 Test method structural test results

Total Weight (g/m2) – 1055                           Thickness (mm) – 0.90

Cut strip tensile strength (lbs. /in.) – Warp = 450 - Weft = 404

Elongation (%) – Warp = 30 - Weft = 47                 Tongue tear (lbs.) – Warp = 87 – Weft = 100

Adhesion (lbs. /in.) – Warp = 9.4 – Weft = 8.9                           Density = 30 X 24.5

Frame: Heavy Duty 1100 Dtex* polyester coated w. plastomer on both sides, UV/Chemical resistant, quadruple overlapped and glued. Canopy:   Heavy duty 100% nylon twill (3/5) w. PU white pigment inner coating, ABT. 0 23mm X 57/58. Wt. AB1.230GR/Sq. M - UV/chemical resistant/fire retardant – UV resistant and water repellent w. a hydrostatic resistance of 250 psi + - Mildew resistant to meet and exceed US Fed. Test MIL.STD.810E 508 - Fire resistance meets and exceeds CPAI 84 SECTION 5 1995, US Fed. Test CFR.1610, meets NFPA701 Flammability Test method 1 (2004), NFPA 702 w. ‘A’ burn scale rating. All seams double stitched and coated both sides.

Floor: PVC of 0.58mm thickness (1,000 Dtex, 18 X 18 polyester) 660 grams per sq. mm 60” W.  

 

Designed to meet and exceed CDC requirement of 12 ACH/HR air exchanges per hour and 0.01 inches of water column of negative pressure when used with appropriate air filtration products.

Standard color is ‘EMS’ Blue exterior w. high visibility white inside color. Green and White exterior canopy color also available at no extra cost. Other colors optional with an extra charge.

All FSI DAT® series Isolation (ISO) Shelters have full privacy zipper closure double door ‘airlock’ in and out dirty entry/clean exit doors, zippered connector flaps on each end to attach one unit to another, air inflation valve, one air inflation hose w. safety cord, pressure relief valve, tie down ropes and 4 D-rings to tie off to, repair kit, manual, carry bag, 2 upper air vents with full velcro closure for isolation applications , clear vinyl windows with full velcro closure flaps for privacy/night use, HVAC hanging air ducts (the number is shelter size dependent) with ties for isolation shelter use, and a hammer.   All canopy walls are velcro’d to the floor air berms for air lock, and reflective striping is found on the upper air vents above doors.   Units can attach to a second shower or FSI shelter. Simply inflate the unit and commence use in approx. 1 - 4 minutes (size of shelter dependent).

Every shelter with a width of over 10 ft - regardless of length and overall size offers a top center air berm running the entire length of the unit at the roof line and secondary full center length air berms running on either side of the main center berm approx. 18 - 24" off center.  FSI offers a total of five 8” - 12" diameter lateral roof support air berms - size of shelter dependent. FSI shelters lead the industry in terms of weight/snow bearing capabilities/strength. Whatever the specification at hand FSI meets and exceeds herein.

Every FSI DAT® series shelter comes complete with electric inflator/deflator, and high pressure scba fitting.

All units supplied w. no charge redundant features allowing for - hanging undress/redress kits etc. on the inlet and outlet side.

Isolation shelters also available with optional pre-hung # F-STRSCR 'PVC strip screens' to allow for bump thru  entry/exit with minimal air flow disruption in all center aisle and side entry man doors to be inside already standard double sided full closure zipper entry/exit doors. Designed to meet and exceed CDC required 12 plus air exchanges per hr.