DAT QE2020S Approx. 7’ W X 7’ L X 8’ H, 50 sq. Ft., 99 lbs. 6 spray nozzle heads, one Multi function Trigger gun. First Responder Portable Haz mat Decon shower system complete.

Description

DAT QE2020S   Approx.  7’ W X  7’ L  X  8’ H,   50 sq. Ft.,  99 lbs.  6 spray nozzle heads, one Multi function Trigger gun.  First Responder Portable Haz mat Decon shower system complete.

 

Files:
Name File size    
2011_dat_qe_shelters 1001.09 KB

decon_manual_2016 5.92 MB

Technical Specs

FSI # DAT® QE2020S First Responder Hazmat Decontamination Shower System

0510mc

 

Frame/Hub: DAT QE Frame/Hub Material Specifications:

Hub is of forged high density polyfibers

Frame Dimensions:

Outer Diameter: 15.72±0.25

Wall Thickness: 1.68±0.25

Carbon Content: 25±2.0%

Specific Gravity: 1.8~2.1

*All testing below use ASTM and National Test standards

Mechanical Properties:

Tensile Strength (ASTM D638, National GB1447-83): L=3000~5200 KG/Cm²; T=2000~5000 KG/Cm²

Tensile Modulus (ASTM D638, National GB1447-83): L= 3.8~6.7×105 ; T= 1.5~6.0×105 KG/Cm²

Flexural Strength (ASTM D790, National GB1449-83): L= 3000~6200; T=2500~5000 KG/Cm²

Flexural Modulus (ASTM D790, National GB1449-83): L=4.9~12.6X105 ; T=1.8~10.6X105 KG/Cm²

Compressive Strength (ASTM D695, National GB1448-83): L=2000~4000; T=1480~3480 KG/Cm²

Shear Strength (ASTM D732, National GB1450-83): L=4540~8600; T=2540~6600 KG/Cm²

Izod Impact Strength (V Type) (ASTM D256, National GB1451-83): L=250~900; T=200~700 KG.CM/ Cm²

Electrical Properties:

Volume Resistance (ASTM D257, National GB1410-78): 1012~1015 Ω.CM

Surface Resistance (ASTM D257, National GB1470-78): 1012~1015

Dielectric Constant (ASTM D150, National GB1409-79): 3~5

 

Dissipation Factor (ASTM D150, National GB1409-79): 0.05

Breakdown Voltage (ASTM D149, National GB1408-78): 13~40 KV/mm

Arc Resistance (ASTM D495, GB1411-78): 60~80(S)

 

QE SERIES® ‘Quick Erect’ General Set up and Tear down Instructions:

All parts are pre-assembled with no special tools required. All components are of interconnected scissor type connected expansion frame components.

To ‘Quick Erect’ simply have 2-4 support personnel grip side frame on each side. Pull the width support frames slowly – and then ease roof frame upwards with the push poles until locked in place. Check and final position canopy and floor. Commence use.

 

Canopy:   Heavy duty 100% nylon twill (3/5) w. PU white pigment inner coating, ABT. 0 23mm X 57/58. Wt. AB1.230GR/Sq. M - UV/chemical resistant/fire retardant – UV resistant and water repellent w. a hydrostatic resistance of 250 psi + - Mildew resistant to meet and exceed US Fed. Test MIL.STD.810E 508 - Fire resistance meets and exceeds CPAI 84 SECTION 5 1995, US Fed. Test CFR.1610, meets NFPA701 Flammability Test method 1 (2004), NFPA 702 w. ‘A’ burn scale rating. All seams double stitched and coated both sides.

Inner canopy: If applicable - of 100% NYLON 210T ANTRON W/R, POLYURETHANE COATED 57/58", Color: White - Flame Retardant to meet 'NFPA-701 TM-1', Anti-fungus/Anti-mildew, opaque

Floor: PVC of 0.58mm thickness (1,000 Dtex, 18 X 18 polyester) 660 grams per sq. mm 60” W.  

 

Standard color is FSI Blue®. Green, White, Tan also available as standard. Other colors offered P.O.A.

 

The DAT®QE2020S comes equipped as standard equipment with an integrally attached ground floor and decon pool that must be set up and placed inside the unit - that will hold up to 100 gallons (400 liters) of water (with an 8”/20 cm berm approx.) before requiring pump out, 2 roll up windows – one on each side, 1 skylight, full closure slip in and out dirty entry/clean exit doors on each end, 4 stainless steel stakes and ground anchor points, one 17”/43 cm HVAC Hanging Duct, 1 small electrical duct, Tie Down Ropes and 4 D-rings to tie off to, Repair kit, manual, shelter sleeve, 2 upper air vents, and hammer. All canopy walls are velcro’d to the floor air berms for air lock, and reflective striping is found on the upper air vents above doors and on entry and exit air berms. Units can attach to a 2nd shower/FSI Shelter.

The DAT®QE2020S also comes complete with a qty. of 7 spray nozzle heads (one overhead) and a single 5’ (150 cm) length of coiled ½”/13 mm hose with an attached multiple function spray gun with spray patterns and flows meant to gently yet thoroughly drench and decon victims. Shutoffs and quick disconnects supplied with every group of shower heads and trigger gun. Flows per shower head and per spray gun = approx. 1 gpm/4 lpm optimum and dependent on water volumes available. 

Simply set up the unit and plug into a water supply. DAT®QE2020S offered with 1 – ¾” (19mm) high pressure 300 psi (20 bar) GHT threaded inlet hose – other fittings available as specified. Decontamination can commence in less than 1 minute.

 

Comes complete with stakes, repair kit

Unit supplied w. no charge redundant features allowing for - hanging undress/redress kits etc. on the inlet and outlet side and - doubling of showering capability in the future.

DAT®QE2020S Approx. 7’ W X 7 L X 8’ H (2.13 M X 2.13 M X 2.43 M), 50 sq. Ft. (4.65M²), 100 lbs. (46 Kg) Carton size approx. = 134 X 73 X 48 cm (53” L X 29” W X 19” H)

 

**All FSI Portable Hazmat Decon Shower Systems are in conformance with the performance requirements of the new ANSI # 113 American National Standard for Fixed and Portable Decontamination Shower Units.